Insulating Bricks
Typical Properties
|
Parameters |
Low Density | Medium Density | |||
| HYPOR 500 | HYPOR 600 | HYPOR 750 | LW 100 | HF110 | |
| Max Service Temperature°C |
1250 |
1250 | 1250 | 1400 | 1450 |
| Bulk Density gms/cc (max) | 0.55 | 0.65 | 0.75 | 1.0-1.1 | 0.8-0.9 |
| Apparent Porisity % (min) | 78 | 72 | 65 | 60 | 65 |
| C.C.S. kg/cm2 (min) | 10 | 12 | 20 | 40 | 30 |
|
Thermal Conductivity (max) (kcal/m/hr/°C) At HF 400°C At HF 600°C At HF 800°C |
123 `3`3 0.11 0.14 0.16 |
13123 `13`23 0.13 0.15 0.16 |
123123 243123 0.16 0.17 0.19 |
123` 123413 0.25 0.28 0.34 |
`23`3 12313 0.22 0.26 0.30 |
|
P.L.C. (%) (max) At °C for 5 Hrs |
±
0.5 1250 |
±
0.5 1250 |
±
0.5 1250 |
±
0.5 1400 |
±
0.5 1450 |
|
Chemical Composition Al2O3 (min) SiO2 (min) Fe2O3 (max) |
213 36.0 56.0 0.8 |
213 36.0 56.0 0.8 |
213 36.0 56.0 1.5 |
213 40.0 55.0 1.5 |
213 45.0 50.0 1.5 |
Size Tolerance: ±
1mm on standard bricks.
± 1% or ± 01.5 mm whichever is greater for shaped bricks.
Cerabond
Insulating Mortar
|
Service Temperature |
1450°C
max. |